Data record tests.bushing-power-factor-and-capacitance.equipment.breaker-oil.maintenance
Verified 2026-10-29 Confidence: High
Bushing Power Factor and Capacitance is specified for medium-voltage and high-voltage oil circuit breakers in maintenance testing at clause 7.6.2.B.9 of ANSI/NETA MTS-2023. The clause calls for power-factor or dissipation-factor tests on each bushing that has a power-factor or capacitance tap, and a hot-collar test where there is none.
Value: medium-voltage and high-voltage oil circuit breakers
| Step | Item | Detail |
|---|---|---|
| Source | ANSI/NETA MTS-2023 | Licensed standard, clause 7.6.2.B.9 |
| Data record | tests.bushing-power-factor-and-capacitance.equipment.breaker-oil.maintenance | Verified 2026-10-29 |
| Entry | Bushing Power Factor and Capacitance | No revisions |
- Subject
- Bushing Power Factor and Capacitance (Test methods)
- Kind
- Equipment fact
- Source
- ANSI/NETA MTS-2023, clause 7.6.2.B.9, Maintenance Testing Specifications for Electrical Power Equipment and Systems, NETA. Publisher page for ANSI/NETA MTS-2023Publisher information page
- Also stated in
- FIST 3-16, section 7.2.4, page 55 (May 2024).
Read the reference passage
7.2.4 Insulation Test
"A power factor test is recommended for this type of breaker as well. [...] Perform a power factor test on the bushings with a hot collar."
FIST 3-16, section 7.2.4, page 55, May 2024. Agency copy of FIST 3-16
The current standard governs; this passage is a public-domain description of the practice dated May 2024.
- FIST 3-16, section 7.2.4, page 55 (May 2024).
History
| Date | Change |
|---|---|
| 2026-10-29 | created |
Cite this page
Cite the governing standard for the fact itself; cite this page as the finding aid.
"Data record tests.bushing-power-factor-and-capacitance.equipment.breaker-oil.maintenance." Circuit Breaker Reference. 2026-10-29. https://www.circuitbreakerreference.com/data/tests.bushing-power-factor-and-capacitance.equipment.breaker-oil.maintenance/.
Circuit Breaker Reference, Data record tests.bushing-power-factor-and-capacitance.equipment.breaker-oil.maintenance (Oct. 29, 2026), https://www.circuitbreakerreference.com/data/tests.bushing-power-factor-and-capacitance.equipment.breaker-oil.maintenance/.
@misc{etr-data-tests-bushing-power-factor-and-capacitance-equipment-breaker-oil-maintenance,
title = {Data record tests.bushing-power-factor-and-capacitance.equipment.breaker-oil.maintenance},
howpublished = {\url{https://www.circuitbreakerreference.com/data/tests.bushing-power-factor-and-capacitance.equipment.breaker-oil.maintenance/}},
organization = {Circuit Breaker Reference},
publisher = {Circuit Breaker Reference},
year = {2026},
note = {last substantive change 2026-10-29}
}{{cite web |title=Data record tests.bushing-power-factor-and-capacitance.equipment.breaker-oil.maintenance |website=Circuit Breaker Reference |publisher=Circuit Breaker Reference |url=https://www.circuitbreakerreference.com/data/tests.bushing-power-factor-and-capacitance.equipment.breaker-oil.maintenance/ |date=2026-10-29 |access-date=}}