Contact Resistance is specified for medium-voltage vacuum circuit breakers in maintenance testing at clause 7.6.3.B.4 of ANSI/NETA MTS-2023. The clause calls for a static contact or pole resistance test on the breaker.
Value: medium-voltage vacuum circuit breakers
| Step | Item | Detail |
|---|---|---|
| Source | ANSI/NETA MTS-2023 | Licensed standard, clause 7.6.3.B.4 |
| Data record | tests.contact-resistance.equipment.breaker-vacuum.maintenance | Verified 2026-10-29 |
| Entry | Contact Resistance | No revisions |
- Subject
- Contact Resistance (Test methods)
- Kind
- Equipment fact
- Source
- ANSI/NETA MTS-2023, clause 7.6.3.B.4, Maintenance Testing Specifications for Electrical Power Equipment and Systems, NETA. Publisher page for ANSI/NETA MTS-2023Publisher information page
- Also stated in
- Stated independently by FIST 3-16, section 2.4, page 10 (May 2024).
Read the reference passage
2.4 Contact Resistance Test
"When performing a contact resistance test, a minimum of 100 Amps shall be used."
FIST 3-16, section 2.4, page 10, May 2024. Agency copy of FIST 3-16
The current standard governs; this passage is a public-domain description of the practice dated May 2024.
- Stated independently by FIST 3-16, section 2.4, page 10 (May 2024).
Read the reference passage
2.4 Contact Resistance Test
"Contact resistance shall not exceed that which was set by the manufacturer's O&M manual. If the manufacturer's O&M manual is not available, the contact resistance shall not exceed 200% of the manufacturer's factory test data. [...] If any readings fail these conditions, further investigation shall be required to determine the root cause."
FIST 3-16, section 2.4, page 10, May 2024. Agency copy of FIST 3-16
The current standard governs; this passage is a public-domain description of the practice dated May 2024.
- Stated independently by FIST 3-16, section 2.4, page 10 (May 2024).
History
| Date | Change |
|---|---|
| 2026-10-29 | created |
Cite this page
Cite the governing standard for the fact itself; cite this page as the finding aid.
"Data record tests.contact-resistance.equipment.breaker-vacuum.maintenance." Circuit Breaker Reference. 2026-10-29. https://www.circuitbreakerreference.com/data/tests.contact-resistance.equipment.breaker-vacuum.maintenance/.
Circuit Breaker Reference, Data record tests.contact-resistance.equipment.breaker-vacuum.maintenance (Oct. 29, 2026), https://www.circuitbreakerreference.com/data/tests.contact-resistance.equipment.breaker-vacuum.maintenance/.
@misc{etr-data-tests-contact-resistance-equipment-breaker-vacuum-maintenance,
title = {Data record tests.contact-resistance.equipment.breaker-vacuum.maintenance},
howpublished = {\url{https://www.circuitbreakerreference.com/data/tests.contact-resistance.equipment.breaker-vacuum.maintenance/}},
organization = {Circuit Breaker Reference},
publisher = {Circuit Breaker Reference},
year = {2026},
note = {last substantive change 2026-10-29}
}{{cite web |title=Data record tests.contact-resistance.equipment.breaker-vacuum.maintenance |website=Circuit Breaker Reference |publisher=Circuit Breaker Reference |url=https://www.circuitbreakerreference.com/data/tests.contact-resistance.equipment.breaker-vacuum.maintenance/ |date=2026-10-29 |access-date=}}