Data record tests.dynamic-contact-resistance.equipment.breaker-sf6.maintenance
Verified 2026-10-29 Confidence: High
Dynamic Contact Resistance is specified for sulfur hexafluoride circuit breakers in maintenance testing at clause 7.6.4.B.4 of ANSI/NETA MTS-2023. The clause lists the dynamic contact or pole resistance test as an optional test beside the static contact resistance test.
Value: sulfur hexafluoride circuit breakers
| Step | Item | Detail |
|---|---|---|
| Source | ANSI/NETA MTS-2023 | Licensed standard, clause 7.6.4.B.4 |
| Data record | tests.dynamic-contact-resistance.equipment.breaker-sf6.maintenance | Verified 2026-10-29 |
| Entry | Dynamic Contact Resistance | No revisions |
- Subject
- Dynamic Contact Resistance (Test methods)
- Kind
- Equipment fact
- Source
- ANSI/NETA MTS-2023, clause 7.6.4.B.4, Maintenance Testing Specifications for Electrical Power Equipment and Systems, NETA. Publisher page for ANSI/NETA MTS-2023Publisher information page
- Also stated in
- FIST 3-16, section 8.3.2, page 69 (May 2024).
Read the reference passage
8.3.2 Dynamic Resistance Measurement
"The DRM is meant to be a comparison between past measurements. A sudden decrease in arcing contact length should be investigated. However, in some cases, the results can indicate other contact problems, including broken contact fingers. [...] The DRM is always taken with a motion analysis."
FIST 3-16, section 8.3.2, page 69, May 2024. Agency copy of FIST 3-16
The current standard governs; this passage is a public-domain description of the practice dated May 2024.
- FIST 3-16, section 8.3.2, page 69 (May 2024).
History
| Date | Change |
|---|---|
| 2026-10-29 | created |
Cite this page
Cite the governing standard for the fact itself; cite this page as the finding aid.
"Data record tests.dynamic-contact-resistance.equipment.breaker-sf6.maintenance." Circuit Breaker Reference. 2026-10-29. https://www.circuitbreakerreference.com/data/tests.dynamic-contact-resistance.equipment.breaker-sf6.maintenance/.
Circuit Breaker Reference, Data record tests.dynamic-contact-resistance.equipment.breaker-sf6.maintenance (Oct. 29, 2026), https://www.circuitbreakerreference.com/data/tests.dynamic-contact-resistance.equipment.breaker-sf6.maintenance/.
@misc{etr-data-tests-dynamic-contact-resistance-equipment-breaker-sf6-maintenance,
title = {Data record tests.dynamic-contact-resistance.equipment.breaker-sf6.maintenance},
howpublished = {\url{https://www.circuitbreakerreference.com/data/tests.dynamic-contact-resistance.equipment.breaker-sf6.maintenance/}},
organization = {Circuit Breaker Reference},
publisher = {Circuit Breaker Reference},
year = {2026},
note = {last substantive change 2026-10-29}
}{{cite web |title=Data record tests.dynamic-contact-resistance.equipment.breaker-sf6.maintenance |website=Circuit Breaker Reference |publisher=Circuit Breaker Reference |url=https://www.circuitbreakerreference.com/data/tests.dynamic-contact-resistance.equipment.breaker-sf6.maintenance/ |date=2026-10-29 |access-date=}}