Data record tests.insulation-resistance.equipment.breaker-oil.acceptance
Verified 2026-10-29 Confidence: High
Insulation Resistance is specified for medium-voltage and high-voltage oil circuit breakers in acceptance testing at clause 7.6.2.B.2 of ANSI/NETA ATS-2025. The clause calls for a one-minute insulation-resistance test on each pole, phase-to-phase and phase-to-ground with the breaker closed and across each open pole, at the manufacturer's test voltage.
Value: medium-voltage and high-voltage oil circuit breakers
| Step | Item | Detail |
|---|---|---|
| Source | ANSI/NETA ATS-2025 | Licensed standard, clause 7.6.2.B.2 |
| Data record | tests.insulation-resistance.equipment.breaker-oil.acceptance | Verified 2026-10-29 |
| Entry | Insulation Resistance | No revisions |
- Subject
- Insulation Resistance (Test methods)
- Kind
- Equipment fact
- Source
- ANSI/NETA ATS-2025, clause 7.6.2.B.2, Acceptance Testing Specifications for Electrical Power Equipment and Systems, NETA. Publisher page for ANSI/NETA ATS-2025Publisher information page
- Also stated in
- FIST 4-7, section 6.1.10.2, page 46 (August 2023).
Read the reference passage
6.1.10.2 Insulation Test
"Standard insulation testing of circuit breakers uses high-voltage dc test equipment to test the insulation between each interrupter, the circuit breaker frame, and the contacts in the open position. This testing is suitable for most circuit breakers to verify that the insulation system of a circuit breaker is functional before bringing it into service. Insulation power factor testing is required for high voltage circuit breakers or for breakers that specify it in the manual."
FIST 4-7, section 6.1.10.2, page 46, August 2023. Agency copy of FIST 4-7
The current standard governs; this passage is a public-domain description of the practice dated August 2023.
- FIST 4-7, section 6.1.10.2, page 46 (August 2023).
History
| Date | Change |
|---|---|
| 2026-10-29 | created |
Cite this page
Cite the governing standard for the fact itself; cite this page as the finding aid.
"Data record tests.insulation-resistance.equipment.breaker-oil.acceptance." Circuit Breaker Reference. 2026-10-29. https://www.circuitbreakerreference.com/data/tests.insulation-resistance.equipment.breaker-oil.acceptance/.
Circuit Breaker Reference, Data record tests.insulation-resistance.equipment.breaker-oil.acceptance (Oct. 29, 2026), https://www.circuitbreakerreference.com/data/tests.insulation-resistance.equipment.breaker-oil.acceptance/.
@misc{etr-data-tests-insulation-resistance-equipment-breaker-oil-acceptance,
title = {Data record tests.insulation-resistance.equipment.breaker-oil.acceptance},
howpublished = {\url{https://www.circuitbreakerreference.com/data/tests.insulation-resistance.equipment.breaker-oil.acceptance/}},
organization = {Circuit Breaker Reference},
publisher = {Circuit Breaker Reference},
year = {2026},
note = {last substantive change 2026-10-29}
}{{cite web |title=Data record tests.insulation-resistance.equipment.breaker-oil.acceptance |website=Circuit Breaker Reference |publisher=Circuit Breaker Reference |url=https://www.circuitbreakerreference.com/data/tests.insulation-resistance.equipment.breaker-oil.acceptance/ |date=2026-10-29 |access-date=}}