Data record tests.trip-and-close-coil-minimum-pickup.equipment.breaker-mv-air.maintenance
Verified 2026-10-29 Confidence: High
Trip and Close Coil Minimum Pickup is specified for medium-voltage air circuit breakers in maintenance testing at clause 7.6.1.3.B.6 of ANSI/NETA MTS-2023. The clause calls for minimum pickup voltage tests on the trip and close coils in accordance with the manufacturer's published data.
Value: medium-voltage air circuit breakers
| Step | Item | Detail |
|---|---|---|
| Source | ANSI/NETA MTS-2023 | Licensed standard, clause 7.6.1.3.B.6 |
| Data record | tests.trip-and-close-coil-minimum-pickup.equipment.breaker-mv-air.maintenance | Verified 2026-10-29 |
| Entry | Trip and Close Coil Minimum Pickup | No revisions |
- Subject
- Trip and Close Coil Minimum Pickup (Test methods)
- Kind
- Equipment fact
- Source
- ANSI/NETA MTS-2023, clause 7.6.1.3.B.6, Maintenance Testing Specifications for Electrical Power Equipment and Systems, NETA. Publisher page for ANSI/NETA MTS-2023Publisher information page
- Also stated in
- Stated independently by FIST 3-8, section 9.5, page 31 (May 2011 (minor revisions 09/27/2021)).
Read the reference passage
9.5 Protection Circuit Low Voltage Testing
"Check breaker trip coils and other devices operated by the relay to ensure that proper operation is obtained at voltages considerably below normal (approximately 56% of normal voltage for breaker trip coils). The value of 56% is 70 volts direct current (Vdc) for a 120-Vdc system. Also check the voltage drop in trip circuits and tripping current."
FIST 3-8, section 9.5, page 31, May 2011 (minor revisions 09/27/2021). Agency copy of FIST 3-8
The current standard governs; this passage is a public-domain description of the practice dated May 2011 (minor revisions 09/27/2021).
- Stated independently by FIST 3-8, section 9.5, page 31 (May 2011 (minor revisions 09/27/2021)).
History
| Date | Change |
|---|---|
| 2026-10-29 | created |
Cite this page
Cite the governing standard for the fact itself; cite this page as the finding aid.
"Data record tests.trip-and-close-coil-minimum-pickup.equipment.breaker-mv-air.maintenance." Circuit Breaker Reference. 2026-10-29. https://www.circuitbreakerreference.com/data/tests.trip-and-close-coil-minimum-pickup.equipment.breaker-mv-air.maintenance/.
Circuit Breaker Reference, Data record tests.trip-and-close-coil-minimum-pickup.equipment.breaker-mv-air.maintenance (Oct. 29, 2026), https://www.circuitbreakerreference.com/data/tests.trip-and-close-coil-minimum-pickup.equipment.breaker-mv-air.maintenance/.
@misc{etr-data-tests-trip-and-close-coil-minimum-pickup-equipment-breaker-mv-air-maintenance,
title = {Data record tests.trip-and-close-coil-minimum-pickup.equipment.breaker-mv-air.maintenance},
howpublished = {\url{https://www.circuitbreakerreference.com/data/tests.trip-and-close-coil-minimum-pickup.equipment.breaker-mv-air.maintenance/}},
organization = {Circuit Breaker Reference},
publisher = {Circuit Breaker Reference},
year = {2026},
note = {last substantive change 2026-10-29}
}{{cite web |title=Data record tests.trip-and-close-coil-minimum-pickup.equipment.breaker-mv-air.maintenance |website=Circuit Breaker Reference |publisher=Circuit Breaker Reference |url=https://www.circuitbreakerreference.com/data/tests.trip-and-close-coil-minimum-pickup.equipment.breaker-mv-air.maintenance/ |date=2026-10-29 |access-date=}}